  Results 1 - 30 of 30 1 

Item #

Item Name

Description

ACS355

ACS355 4X

MTAC-01 Pulse Encoder The Pulse Encoder Interface module offers a differential or single ended interface for a digital pulse encoder connection. The module is capable of operating from either a 15 or 24 VDC signal with a maximum frequency of 200kHz. x N/A
MPOT-01 Speed Pot, Start / Stop & Fw/Rev Switches Potentiometer with two switches: Start/Stop and Forward/ Reverse. Polarity is selected with DIP switches. No external power source is needed for the potentiometer. This option can be used with the Blank Cover, Basic or Advanced Panel. x N/A
FDNA-01-KIT DeviceNet Adapter The DeviceNet network uses a linear bus topology. Terminating resistors are required on each end of the trunk line. Drop lines as long as 6 meters (20 feet) each are permitted, allowing one or more nodes to be attached. DeviceNet allows branching structures only on drop lines. x x
FPBA-01-KIT PROFIBUS-DP Adapter PROFIBUS is an open serial communication standard that enables data exchange between all kinds of automation components. The physical transmission medium of the bus is a twisted pair cable (according to the RS-485 standard). The maximum length of the bus cable is 100 to 1200 meters, depending on the selected transmission rate. Up to 31 stations can be connected to the same PROFIBUS system without the use of repeaters. x x
FCAN-01-KIT CANopen Adapter

CANopen is a higher layer protocol based on the CAN (Control Area Network) serial bus system and the CAL (CAN Application Layer). CANopen assumes that the hardware of the connected device has a CAN transceiver and a CAN controller as specified in ISO 11898. The CANopen Communication Profile, CiA Ds301, includes both cyclic and event driven communication, which makes it possible to reduce the bus load to minimum while still maintaining extremely short reaction times. High communication performance can be achieved at relatively low baud rates, thus reducing EMC problems and cable costs. CANopen device profiles define both direct access to drive parameter and time critical process data communication. The FCAN-01 module fulfills CiA (CAN in Automation) standard DSP 402 (Drives and Motion Control).

x x
FMBA-01-KIT Modbus RTU Adapter

Modbus is a serial, asynchronous protocol. The Modbus protocol does not specify the physical interface. Typical physical interfaces are RS-232 and RS-485. The FMBA-01 provides a galvanically isolated RS-485 interface. Modbus is designed for integration with Modicon PLCs or other automation devices, and the services closely correspond to the PLC architecture. The FMBA-01 supports the RTU protocol only.

x x
FENA-01-KIT Ethernet IP/Modbus TCP Adapter

The FENA-01 module supports both Modbus®-TCP and EtherNet/IP™ network protocols. The Modbus-TCP protocol is simply the Modbus protocol used on top of Ethernet-TCP/ IP. Modbus-TCP is an open Industrial Ethernet network which has been specified by the Modbus-IDA User Organization. EtherNet/IP is based on the Common Industrial Protocol (CIP), which is also the framework for both the ControlNet and DeviceNet network protocols. The FENA-01 supports 10/100 Mbps transfer rate with network connections made with CAT 5 wiring and RJ-45 connectors. Both star and bus topology options are supported.

x x
SREA-01-KIT Ethernet Adapter (Gateway)

SREA-01 is an optional device for web browser based remote interface to the ACS310 and ACS355 drives via ethernet. This din rail mounted adapter enables remote data acquisition through a standard web browser, utilizing an internal web server for drive configuration and access. Multiple drives (up to 10) can be connected to the Modbus-RTU network through the drive’s Modbus-RTU port. The ACS355 and ACS550 can also be connected through the control panel port, although an additional RS-485 converter is needed for each drive if several drives are connected by their panel port..

x x
FRSA-00 Modbus RTU PCB

Similar to the FMBA-01-KIT except as a bare, coated printed circuit board (PCB) with the RS-485 GND as the same potential as the drive I/O GND.

x x
MFDT-01 FlashDrop

FlashDrop is a powerful palm sized tool for fast and easy parameter selecting and setting. It gives the possibility to hide selected parameters to protect the machine. Only the parameters needed in the application are shown. The tool can upload/download parameters, copy parameters between two drives or between a PC and a drive. Includes DrivePM (Drive Parameter Manager) which is a software tool to create, edit and copy parameter sets for FlashDrop. The parameter sets can consist of all parameters or only a set of the user parameters.

x x
ACS-CP-A Advanced Control Panel

The Advanced Control Panel includes a full graphic, backlite display capable of displaying three Actual Signal values or bar graphs. The Alpha-Numeric display supports thirteen languages. A Real Time Clock is also included. This panel supports the internal Sequence Programming Function..

x Standard
ACS-CP-C Basic Control Panel

The Basic Control Panel includes a single line numeric backlit LCD display.

x N/A
OPMP-01 Cabinet Panel Mounting

Control Panel Mounting Platform allows remote mounting of the keypad on a larger enclosure or remote panel. The kit maintains UL Type 12 integrity of the mounting location. Adapters, 3 m (10 ft) cable and mounting hardware are included in this kit. With this mounting arrangement, the keypad is removable from the panel in a fashion identical to a drive-mounted keypad.

x x
ACS/H-CP-EXT Control Panel Mounting

Control Panel Mounting Platform allows remote mounting of the keypad on a larger enclosure or remote panel. The kit maintains UL Type 12 integrity of the mounting location. Adapters, 3 m (10 ft) cable and mounting hardware are included in this kit. With this mounting arrangement, the keypad is removable from the panel in a fashion identical to a drive-mounted keypad.

x x
OPCA-01 RJ45/DB9 Adapter

This adapter converts the drive’s panel port RJ45 (CAT 5 cable connector) plug to a 9 pin RS-232 computer serial port connector for connecting the drive to a PC.

x x
3AFE64532871 DriveWindow Light 2.x

DriveWindow Light is software designed for online drive commissioning and maintenance purposes. It is possible to adjust parameters, read the actual values and control the drive with DriveWindow Light instead of the drive control panel. It is also possible to follow trends and draw graphs. An RJ45 to DB9 adapter cable (OPCA-01) is provided to permit connection between the panel port and a PC.

x x
3AUA0000041141 DriveBrowser DriveBrowser software is designed for online drive commissioning and maintenance purposes. DriveBrowser uses a computer’s standard Ethernet port to connect to an EtherNet/IP or Modbus-TCP network. It is compatible with the ACS355, ACS550, ACH550 and ACS800* drives (*ACS800 standard control program). Drives require configuration and connection to an EtherNet/IP or Modbus-TCP network. DriveBrowser supports Microsoft Windows operating systems (Windows NT4, 2000, XP & Vista).
• Configure network connections
• Parameter editing and monitoring
• Upload/download drive parameter files, save, print
• Compare files
• Trending up to four signals
• Drive Control for commissioning and test
x x
OCAT-01 Panel Extension Cable 7 foot CAT 5 patch cable allows remote operation of the standard panel or connection of the drive to a PC using the RJ45/DB9 Adapter (OPCA-01) which must be purchased separately. x N/A
ACS150/350-PROGCASE ACS150/350 Programming Case Powered by 115VAC, the Programming Case includes an ACS150 and ACS355 drive mounted on a panel. Included is an I/O board with switches, pots, meters and LEDs permitting remote operation. x N/A
ACS55/150/350-DISPCASE ACS355 Display Case

The Display Case provides an ACS55, ACS150 and an ACS355 along with options ACS50-POT, MPOT-01, one Fieldbus Adapter, ACS-CP-A, ACS-CP-C and MTAC-01 mounted loosely inside a foam packed suitcase.

x N/A
MUL1-R1 NEMA 1 Enclosure Kit

This option provides the necessary hardware to modify the ACS310 or ACS355 drive from the standard fingersafe protected chassis to NEMA 1 protection capable of landing conduit. MUL1-R1 kit is used with frame sizes R0 through R2, MUL1-R3 is used with frame size R3, and MUL1-R4 is used with frame size R4.

x N/A
MUL1-R3 NEMA 1 Enclosure Kit

This option provides the necessary hardware to modify the ACS310 or ACS355 drive from the standard fingersafe protected chassis to NEMA 1 protection capable of landing conduit. MUL1-R1 kit is used with frame sizes R0 through R2, MUL1-R3 is used with frame size R3, and MUL1-R4 is used with frame size R4.

x N/A
MUL1-R4 NEMA 1 Enclosure Kit

This option provides the necessary hardware to modify the ACS310 or ACS355 drive from the standard fingersafe protected chassis to NEMA 1 protection capable of landing conduit. MUL1-R1 kit is used with frame sizes R0 through R2, MUL1-R3 is used with frame size R3, and MUL1-R4 is used with frame size R4.

x N/A
ACS/H-CP-EXTIP66 NEMA 4X Cabinet Panel Mounting

Allows remote mounting of the ACS-CP-X Operator Panels on a larger NEMA 4X (IP66) enclosure or remote panel. The kit maintains NEMA 4X integrity of the mounting location. All necessary hardware and a mounting template are provided in addition to a 3m panel cable. When mounted, the operator is not removable from the front of the enclosure. The operator panel must be purchased separately.

x N/A
ACS355-DEMOCASE ACS355 Demo Case

Powered by 115VAC, the DemoCase includes an ACS355 drive mounted on a panel. Included is a motor and I/O board with switches, pots, meters and LEDs permitting remote operation of the drive and motor.

x N/A
MREL-01 Relay Output Module Extension

The Relay Output Extention module (MREL) is an interface for connecting three (3) FORM C relay outputs. The MREL- 01 is supported from SW version 2.57C and onwards for the ACS355 and is supported by all SW version of ACS310.

x N/A
MGLND-01 Cable Gland Kit

Water tight conduit fittings. Includes necessary conduit fittings in a plastic bag. Refer to ACS355 Supplemental User‘s Manual for installation instructions.

R1 Frame
MGLND-01

Kit Part #: 3AUA0000059068

N/A x
MGLND-03 Cable Gland Kit

Water tight conduit fittings. Includes necessary conduit fittings in a plastic bag. Refer to ACS355 Supplemental User‘s Manual for installation instructions.

R3 Frame
MGLND-03

Kit Part #: 3AUA0000059069

N/A x
MPCV-01 Pressure Compensation Valve

Provides a barrier against dirt, dust, and liquid while allowing the drive enclosure to breathe during environmental conditions.

N/A x
MPOW-01 Auxiliary Power Module

The optional auxiliary power module enables the drive.

x N/A
  Results 1 - 30 of 30 1 